EUROPE


Large Displacement Range

J-series

Large Displacement Range J-series J240/SA4AM

J-series accommodates high velocity and large displacement testing
Long duration shock tests require high velocity and large displacement.
J-series is a high-functionality system that offers usability and durability furnished with functions that accommodate high velocity and large displacement testing.

Features

Features

■ Expanded maximum test range

・Maximum velocity of Sine force: 2.4m/s

・Maximum velocity of Shock force: 4.6m/s

・Maximum displacement: 100mmp-p

■ Patented upper (armature) support system PS Guide

Parallel Slope Guide is standard

■ Low noise

Optimised design of the air intake based on fluid dynamics has reduced the air-intake noise.

■ All models can be directly coupled to a climatic test chamber

Table Insert Pattern (Unit:mm)

Table Insert Pattern(Unit:mm)

Table Insert Pattern Table Insert Pattern

Specifications

  System Model J230/
SA3AM
J230S/
SA7AM
J240/
SA4AM
J240S/
SA6HAM
J250/
SA5AM
J250/
SA6AM
J260/
SA7AM*7
J260S/
SA16HAM*7
  Data Sheet
  Frequency Range(Hz) 0-3000 0-3000 0-2400 0-2400 0-2200 0-2200 0-2600*4 0-2000
System
Specifications
Rated
Force
Sine(kN) 16 16 24 24 35 40 54 54
Random
(kN rms)*1
16 16 24 24 35 40 54 54
Shock(kN) 40 40 55 70 70 80 108 196
Maximum
Acc.
Sine(m/s2) 941 888 923 857 777 888 857 857
Random
(m/s2 rms)
658 622 646 600 544 622 600 600
Shock
(m/s2 peak)
2000 2000 2000 2000 1555 1777 1714 2000
Maximum
Vel.
Sine(m/s) 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
Shock
(m/s peak)
2.4 3.5 2.4 3.6 2.4 2.4 2.4 4.6
Maximum
Dsp.
Sine(mmp-p) 100 100 100 100 100 100 100 100
Maximum
Travel
(mmp-p)
120 120 120 120 120 120 116 116
Maximum Load(kg) 300 300 400 400 600 600 1000 1000
Power Requirements
(kVA)*2
28 38 38 52 53 57 86 127
Breaker Capacity(A)*3 50 75 75 100 100 100 150 225
Vibration
Generator
Model J230 J230S J240 J240S J250 J250 J260 J260S
Armature Mass(Kg) 17 18 26 28 45 45 63 63
Armature Diameter
(φmm)
200 200 290 290 440 440 446 446
Allowable Eccentric
Moment(N・m)
700 700 850 850 1550 1550 1550 1550
Dimensions(mm)
W×H×D
1124
×
1079
×
850
1124
×
1079
×
850
1234
×
1145
×
890
1234
×
1145
×
890
1463
×
1301
×
1100
1463
×
1301
×
1100
1527
×
1319
×
1100
1657
×
1319
×
1100
Shaker Body
Diameter(mm)
630 630 720 720 860 860 920 920
Mass(kg) 1800 1800 2400 2400 3500 3500 4100 5000
Power
Amplifier
Model SA3M-
J30
SA7M-
J30S
SA4M-
J40
SA6HAM-
J40S
SA5M-
J50
SA6M-
J50
SA7M-
J60
SA16HAM-
J60S
Maximum Output(kVA) 23 30 34 40 50 57 70 76
Dimensions(mm)
W×H×D
580
×
1950
×
850
580
×
1950
×
850
580
×
1950
×
850
1160
×
1950
×
850
580
×
1950
×
850
580
×
1950
×
850
1160
×
1950
×
850
2900
×
1950
×
850
Mass(kg) 330 500 440 1200 880 910 1400 3200
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
Blower Dimensions
(mm)
W×H×D*5
1044
×
2285
×
704
1044
×
2285
×
704
929
×
2175
×
534
929
×
2175
×
534
1160
×
2405
×
787
1160
×
2405
×
787
1160
×
2405
×
787
1160
×
2405
×
787
Mass(kg) 150 150 150 150 250 250 250 250
Wattage(kw) 3.7 3.7 5.5 5.5 11 11 15 15
Duct Hose
Diameter(φ)
200 200 200 200 250 250 250 250

Ecology

Eco Specifications

  System Model J230/EM3AM J240/EM4AM J250/EM5AM J250/EM6AM J260/EM7AM*7
  Data Sheet
  Frequency Range(Hz) 0-3000 0-2400 0-2200 0-2200 0-2600*4
System
Specifications
Rated
Force
Sine(kN) 16 24 35 40 54
Random
(kN rms)*1
16 24 35 40 54
Shock(kN) 40 55 70 80 108
High Velocity Shock*6
(kN)
30 48 68 77 96
Maximum
Acc.
Sine(m/s2) 941 923 777 888 857
Random
(m/s2 rms)
658 646 544 622 600
Shock
(m/s2 peak)
2000 2000 1555 1777 1714
High Velocity Shock*6
(m/s2 peak)
1764 1846 1511 1711 1523
Maximum
Vel.
Sine(m/s) 2.4 2.4 2.4 2.4 2.4
Shock
(m/s peak)
2.4 2.4 2.4 2.4 2.4
High Velocity Shock*6
(m/s peak)
3.5 3.5 3.5 3.5 3.5
Maximum
Dsp.
Sine(mmp-p) 100 100 100 100 100
High Velocity Shock*6
(mmp-p)
100 100 100 100 100
Maximum Travel(mmp-p) 120 120 120 120 116
Maximum Load(kg) 300 400 600 600 1000
Power Requirements
(kVA)*2
28 38 53 57 86
Breaker Capacity(A)*3 50 75 100 100 150
Vibration
Generator
Model J230 J240 J250 J250 J260
Armature Mass(kg) 17 26 45 45 63
Armature Diameter(φmm) 200 290 440 440 446
Allowable Eccentric
Moment(N・m)
700 850 1550 1550 1550
Dimensions(mm)
W×H×D
1124
×
1079
×
850
1234
×
1145
×
890
1463
×
1301
×
1100
1463
×
1301
×
1100
1527
×
1319
×
1100
Shaker Body
Diameter(mm)
630 720 860 860 920
Mass(kg) 1800 2400 3500 3500 4100
Power
Amplifier
Model EM3AM-J30 EM4AM-J40 EM5AM-J50 EM6AM-J50 EM7AM-J60
Maximum Output(kVA) 23 34 50 57 70
Dimensions(mm)
W×H×D
580
×
1950
×
850
580
×
1950
×
850
1160
×
1950
×
850
1160
×
1950
×
850
1160
×
1950
×
850
Mass(kg) 380 490 930 960 1400
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
Blower Dimensions(mm)
W×H×D*5
1044
×
2285
×
704
929
×
2175
×
534
1160
×
2405
×
787
1160
×
2405
×
787
1160
×
2405
×
787
Mass(kg) 150 150 250 250 250
Wattage(kw) 4 4 11 11 15
Duct Hose
Diameter(φ)
200 200 250 250 250
  • *1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
  • *2 Power supply: 3-phase 380/400/415/440 V, 50/60 Hz. A transformer is required for other supply voltages.
  • *3 In case of 400 V
  • *4 Above 2000 Hz, the force rolls-of f at a rate of -12 dB/oct.
  • *5 Spec described above is in case of 50Hz. Dimension is changed in case of 60Hz.
  • *6 In case of high velocity option
  • *7 Export License is required for exporting the shaker system of over 50 kN Sine force.
  • * The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70% must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
  • * In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  • * Frequency range values vary according to sensor and vibration controller.
  • * Armature mass and acceleration may change when chamber is combined.