EUROPE


Seismometers

Seismic monitoring system with display (SW-74)

A popular seismometer with display
SW-74 uses high resolution servo accelerometer which can detect micro earthquakes.
Seismic monitoring system with display (SW-74)

Features

  • ■ Indication function

    Importance level of information is shown by back color. It can be recognized even by remote watching. On earthquake ocurrence, “ocurrence time”, “peak acceleration”, “seismic intensity scale (measured seismic intensity)” are displayed.

    Indication function

  • ■ Memory function

    Memory function

    Up to 50 time histories can be saved.
    *Option software is needed to export waveform data.

  • ■ Alarm setting

    Alarm setting

    3-step alarm output by acceleration is possible. Alarm level is possible to be set.

  • ■ Easy to operate

    Easy to operate

    Touch panel is adopted. Easy operation makes speedy confirmation in an emergency.

  • ■ Alarm setting

    Compact size makes easy installation. It can be stored in a rack.

  • ■ Power supply

    Select from AC 100 V or DC 24 V (Option)

  • ■ Waveform observation

    Waveform observation

    By connecting with PC on which the option software is installed, various settings of the device and seismic waveform data stored in the internal memory can be acquired.

System composition

System composition

Outward dimensions

Outward Drawing

Specifications

Item Specification
Display element STN monochrome LCD with touch switch / back light color : green / orange / red
Display
contents
Earthquake monitor display Present time
Earthquake generation display Earthquake generation time, maximum acceleration, seismic intensity scale, alarm operation
Alarm hold display Avobe + reset button (whole reset of alarm / buzzer)
Setting display Trigger, alarm, date & time
Maintenance display Pickup test, earthquake history
Alarm and buzzer Upper limit 3-step (ALM1– 3), individual setting, buzzer for point,
Acceleration : 0.1– 999.9 gal (setting interval : 0.1 step, 0.0 is alarm operation OFF)
Alarm and buzzer
reset method
a. Automatic reset by an internal timer 1 – 9999 sec. (setting interval 1 sec., 0 is automatic reset OFF)
b. External reset terminals (all steps reset by non-voltage [a] contact)
c. Reset button on the touch panel (effective on display alarm)
FAULT alarm (Power failure)1a / 1b contact switching type
Contact rating : 2 A 30 VDC (maximum allowable voltage / current : 220VDC/2A)
Serial output For maintenance (conforms to RS232C ) : MC1 (switch over)
For external display (conforms to RS422) : MC2
For printer (conforms to RS232C)  : MC2
Back up unit Backup time > 10 min. (ready time), charging time < 48 hours
(no function at the operation by optional power 24 VDC )
Mounting method Wall hanging
Operational temperature
range
0 to + 50 °C
Operational humidity range 0 to + 50 °C
10 to 85 %RH (non-condensing)
Power supply AC 100 V ± 10 %, less than 50 VA / DC2 4 V ±10 %, less than 35 W (option)
Mass Aprox. 3 kg

Option

  • ■ External display (ED74)

    External display (ED74)

    Indicates acceleration amplitude, seismic intensity
    scale and alarm occurence time.

  • ■ Multiple control unit (2 out of 3) CU-5

    ■ Multiple control unit (2 out of 3) CU-5

    This device makes reliability of the relay contact output of
    the alarm signal to control or stop activation higher.
    An alarm signal is output when 2 units out of 3 generate
    alarm signals.